RAAC in Sweden

RAAC began in Sweden.This is what its planks have taught us, and what that means for yours.

Aerated concrete is a Swedish invention. Reinforced planks made under Swedish licences went on to roof schools, halls and factories across Britain and Europe. In 2024, engineers at Lund University tested 65 year old Swedish roof planks to failure. Here is the story, the evidence, and how we use it.

Close view of aerated concrete, showing the small air pores through the material
Aerated concrete, close up
  • 1924Patent applied for in Sweden 2
  • 65yearsIn service before the Lesjöfors planks were tested 1
  • 5.2kN/m²Carried on top of their own weight before failing 1
  • 2.6 to 3.5×Safety factor in bending against the 1950 design snow load 1
1924Where it began
A Swedish invention

A material that would insulate and carry load

That was the aim. Axel Eriksson, an architect and building scientist, applied for his patent on aerated concrete on 27 May 1924 2. Production began in 1929. The material was first sold as steam cured aerated concrete, and in 1940 it took the trade name Ytong. In 1934 a second company began making a competing product, Siporex. Several factories were built in Sweden, and the material was made under licence in a large number of countries 1.

Reinforced roof and floor elements followed, and they travelled. In June 1959 a Scottish newspaper reported that Costain had bought the sole Siporex rights for Britain and Ireland, with a plant planned at Newarthill to make reinforced roof and floor slabs 7. RAAC reached the UK from the late 1950s under names including Siporex, Durox, Ytong and Celcon, and most roof and floor panels were marketed here between 1963 and 1968 6.

In Sweden, until about 1980, reinforced aerated planks spanning up to five or six metres were something of a standard solution for the roofs of hall buildings, laid between the main beams. They were also used in schools, offices and homes of the period 1.

The same invention, made under licence, the same kind of plank. Which is why a Swedish test programme matters to a roof in Reading, Glasgow or Rotterdam.

Anatomy of a plank

Inside a 1958 Swedish roof plank

The planks Lund University tested came from an industrial hall at Lesjöfors, in Filipstad, completed in 1958. This is the end of one, resting on its support, drawn to scale from the report 1.

End of a 1958 Swedish RAAC roof plank over its support Long section of the plank end, 145 mm deep, with plain 10 mm bars top and bottom at about 15 mm cover, three welded cross bars at the end, the first about 25 mm from the end face, and a bearing of 50 mm on the support. 145 mm 50 mm 123456
  1. Plain round bars, 10 mm, top and bottom, with about 15 mm of cover. Plain bars have limited bond with aerated concrete.
  2. Corrosion protection was a cement slurry coating. Corrosion was found along the whole length of the bars, though it was superficial and had not reduced their section.
  3. Three welded cross bars, 10 mm, at each end anchor the plain bars. The outermost sits about 25 mm from the end face. The other two are shown at indicative spacing.
  4. A closed link, 6 mm, welded to the main bars at each end.
  5. Aerated concrete at 640 kg/m³. Cores taken from the planks gave compressive strengths of 1.14 and 1.7 MPa, well below what was expected.
  6. Bearing. A 1961 Swedish handbook records roof planks designed for a bearing of at least 50 mm, so that the outermost cross bar sits over the support. The 1993 Swedish handbook asked for more than 50 to 60 mm 1. The IStructE now recommends a minimum of 75 mm 6.
5 mLength
0.5 mWidth
145 mmDepth
640kg/m³ density
15 mmCover, approx.
1958Year built
Lund University, 2024

Tested to failure, 65 years on

The pilot study, funded by Boverket and prompted by the UK experience, took five of the least damaged planks from the Lesjöfors roof into the laboratory. Even after 65 years of service and being dismantled, they showed good capacity in bending and in shear 1.

Design snow load when the hall was built, 1950 rules

1.5 to 2.0

Characteristic snow load on the roof today

2.0

Load carried before failure, on top of self weight

5.2 kN/m²
2.6 to 3.5×The safety factor against failure in bending, significantly higher than was required when the hall was built. The report's conclusion: safety against failure is clearly met as long as there is no serious damage and the planks have not been altered 1.
How a plank warns you

Deflection is the signal

The planks' initial bending stiffness was relatively low. In the final stage the plain bars worked like a cable hanging between their anchorages, and even at around 200 mm of deflection the planks did not collapse 1. Three numbers worth knowing:

Deflection of a 5 m RAAC plank at span/100, span/50 and span/25 Three deflected shapes over a 5 metre span: 50 mm at span/100, the UK indicator that a plank may be close to capacity; 100 mm at span/50, seen in service at the low points of the Lesjöfors roof; and 200 mm at span/25, reached in the laboratory without collapse. Vertical scale exaggerated four times. 50 mm100 mm200 mm supportsupport 5 m span · vertical scale ×4
span/100

50 mm on a 5 m span. UK guidance: deflection beyond this could indicate a plank is close to capacity 9.

span/50

100 mm. Seen in service at the low points of the Lesjöfors roof, where it drained internally. Water leaks and freezing are the suggested cause 1.

span/25

200 mm. Reached in the laboratory without collapse, when the test was stopped 1.

A laboratory plank is not a plank in a roof. The 2018 collapse at a school in England happened suddenly, with little or no warning 8. Deflection tells you something only if someone is measuring it.

What Swedish engineers look for

Five warning signs, easy to see

The report judges the risks in Sweden to be limited in general, because damage is usually preceded by warning signs that are easy to see. Significant damage near the supports must lead to immediate action 1.

Spalling and delamination

Especially near the supports.

Significant cracking

Across or along the plank.

Large deflections

Sag you can see from the floor.

Visible corrosion

Rust staining or exposed bars.

Water leaks

Stains, damp and ponding above.

The record

Where RAAC was used in Sweden, and where it was not

A lot gets written about RAAC in Sweden. This is what the sources support.

Supported

Hall roofs

Until about 1980, reinforced planks spanning up to five or six metres were a standard roof solution for hall buildings 1.

Supported

Schools, offices and homes

Reinforced elements were also used in buildings of these types from the same period 1.

No source found

Million Programme housing

Sweden built 1,005,578 homes between 1965 and 1974 3. We have found no source showing RAAC planks were used widely in them. Use in floors between flats was probably unusual, because of sound insulation 1.

Reading Swedish documents

Four words to look for

If you are working from Swedish drawings, manufacturer literature or reports, RAAC appears under several names 1.

HistoricalGasbetong

Aerated concrete. Also lättbetong, lightweight concrete.

RAACArmerad gasbetong

Reinforced aerated concrete: planks, slabs and lintels.

Technical, currentAutoklaverad lättbetong

The current Swedish standards term.

Not RAACBlåbetong

Blue concrete, the alum shale version. A radon issue, below.

1,000Bq/m³ radon, around

Blåbetong: a different Swedish problem

Aerated concrete made with alum shale was produced at several places in Sweden between 1929 and 1975 5. It gives off radon, and Boverket notes levels of around 1,000 Bq/m³ can occur where it is in walls and floors 4. Production stopped in 1975 1. It is a radiation question, not a structural one, and it is not what a RAAC structural assessment is about.

What it means for your roof

Find out what is in the plank. Never assume it.

The most useful line in the Swedish report is not about strength. The original manufacturers' documentation was never transparent, so the design and amount of reinforcement in an existing plank is uncertain, and the calculation method in SS-EN 12602 (2016) cannot be used to verify the capacity of reinforced aerated concrete elements in older buildings 1. Every roof is unique. That is how we work, through the five stages of our RAACSafe Protocol.

  1. Assess

    Non-destructive radar and ultrasonic scanning with the building in use. Our own software turns the scan into a plank by plank layout.

  2. Design

    Findings assessed against the IStructE RAAC guidance and signed by a Chartered Engineer and Fellow of the IStructE.

  3. Manufacture

    The UK's first CFRP system designed specifically for RAAC, made in the UK to the design for that roof.

  4. Install

    Strengthened in place. Tailored, because over-strengthening moves the problem into compression.

  5. Monitor

    Our instrumented monitoring devices are in active service on RAAC roofs today.

Already delivered
Critical infrastructureRAAC strengthening in service
EducationRAAC strengthening in service
RailRAAC strengthening in service

We work across Europe, wherever RAAC takes us. If the project is big enough, we will be there.

Tell us about your building
Timeline

A century of RAAC, from Sweden outwards

  1. 1924Patent

    Axel Eriksson, a Swedish architect and building scientist, applies for a patent on aerated concrete on 27 May. 2

  2. 1929Production

    Production begins in Sweden. The material is sold as steam cured aerated concrete and takes the trade name Ytong in 1940. 1

  3. 1934Siporex

    A second Swedish company starts making a competing product, Siporex, later made under licence in a large number of countries. 1

  4. 1958Lesjöfors

    An industrial hall at Lesjöfors, Värmland, is roofed with reinforced aerated concrete planks. They are tested to failure 65 years later. 1

  5. 1959To Britain

    Costain is reported to have bought the sole Siporex rights for Britain and Ireland, with a plant planned at Newarthill for reinforced roof and floor slabs. 7

  6. 1963 to 1968UK peak

    The years in which most RAAC roof and floor panels were marketed in the UK. 6

  7. 1965 to 1974Million Programme

    1,005,578 homes are built in Sweden in ten years. 3

  8. 1975Alum shale ends

    Swedish aerated concrete made with alum shale stops being produced, because of radon. 1

  9. 2018Collapse

    A flat RAAC roof at a school in England collapses suddenly, with little warning. 8

  10. 2019UK alert

    The Standing Committee on Structural Safety issues its alert on RAAC planks. 8

  11. 2024Lund

    Lund University publishes a Boverket funded assessment of reinforced aerated concrete in Swedish buildings, with laboratory tests. 1

Questions

RAAC in Sweden,answered


Where was RAAC invented?
In Sweden. Axel Eriksson applied for his patent on aerated concrete in 1924, production began in 1929, and reinforced roof and floor elements followed. Swedish processes, sold under names such as Ytong and Siporex, were then made under licence in many countries, the UK among them.
What is RAAC called in Swedish?
Historically gasbetong or lättbetong. Reinforced elements are armerad gasbetong, and the current technical term is autoklaverad lättbetong. These are the words to look for in Swedish drawings, manufacturer literature and reports.
Is RAAC a problem in Sweden?
A 2024 study by Lund University, funded by Boverket, judged the risks in Sweden to be limited in general, because damage is usually preceded by warning signs that are easy to see. It also records that concerns about damage and poor quality have been raised in Sweden, particularly in halls with spans of five to six metres, and that significant damage near the supports must lead to immediate action.
Was RAAC used in the Million Programme?
We have found no source that shows reinforced aerated concrete planks were used widely in Million Programme housing. The Lund University report says reinforced elements were used in homes, schools and offices of that era, but that their use in floors between flats was probably unusual, because of sound insulation. Their standard use was as roof planks on hall buildings.
What is blåbetong, and is it the same as RAAC?
Blåbetong, blue concrete, is aerated concrete made with alum shale. It was produced in Sweden between 1929 and 1975 and gives off radon. It is a radiation question, not a structural one, and it is not what a RAAC structural assessment is about.
What did the Lund University tests show?
Five roof planks from a 1958 hall at Lesjöfors were tested in the laboratory. Even after 65 years of service and dismantling, they showed good capacity in bending and in shear. They carried 5.2 kN/m² on top of their own weight before failing, against a design snow load of 1.5 to 2.0 kN/m² when the hall was built: a safety factor of 2.6 to 3.5 in bending. Other planks in the same roof, at its low points, had sagged by around 100 mm over a 5 m span.
Can today's standard be used to check an old RAAC plank?
The Lund University report concludes that the calculation method in SS-EN 12602 (2016) cannot be used to verify the capacity of reinforced aerated concrete elements in older buildings, and that there are no reliable models for their bending and shear capacity. What is in the plank has to be found out, not assumed.
Do you work in Sweden and the rest of Europe?
Yes. We work across Europe, wherever RAAC takes us, on projects of sufficient scale. Survey, engineering assessment, CFRP design, manufacture, installation and monitoring are carried out by the same team, wherever the building is.
Get in touch

Talk to the engineerwho designs it


Tell us what you know about the building and what has been found so far. A RAAC surveyor and a chartered structural engineer read every enquiry.

Tell us about your RAAC

Free initial advice from a RAAC surveyor and a structural engineer.

We reply within one working day. Your details go straight to our team and are not shared with anyone else.

Thank you, that is with us.

We reply within one working day. If it is urgent, call +44 118 430 8430.

Chat on WhatsApp